Open Access
Table A1
Selection of the walls of which the spectra are depicted in Figure A1, and their properties.
Code name | Weighted sound reduction index | Spectrum C (Pink noise weighted by A) | Pink noise weighted by isophone 40 | Indoor spectrum weighted by A filter | Indoor spectrum weighted by isophone 40 | Loudness |
||||
---|---|---|---|---|---|---|---|---|---|---|
Pink noise |
Indoor noise |
|||||||||
R
w
|
Rw + C50–5000 |
Rw + C100–3150 |
Rw + C50–3150 |
Rw + C100–5000 |
Rw + I40 |
Rw + indoorA |
Rw + indoor40 |
N
|
N
|
|
dB | dB | dB | dB | dB | dB | dB | dB | Sone | Sone | |
21_HW_59 | 59 | 58 | 58 | 57 | 58 | 60 | 62 | 63 | 0,205 | 0,122 |
30_LW_66 | 66 | 58 | 64 | 57 | 65 | 65 | 69 | 73 | 0,111 | 0,006 |
17_HW_56 | 56 | 55 | 55 | 55 | 56 | 56 | 57 | 57 | 0,402 | 0,322 |
36_LW_69 | 69 | 52 | 66 | 51 | 65 | 59 | 64 | 67 | 0,393 | 0,076 |