Open Access

Table 2

Geometrical and numerical parameters of the simulations. See definitions in Figure 7. All lengths are in mm. The total guide length is L = L' + LBi for i = 1, 2, 3 according to the termination.

a L ' s LB1 LB 2 LB 3 R d h b α
88 1210 40 120 280 110 300 53 15 30 20°

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.