Open Access

Table 3

The seat and floor types with the estimated effective seat back rest heights* (the unobstructed part of the seat back rest) together with the calculated main dip frequencies** with effective seat backrest corresponding to λ/4, as well as the measured main attenuation dip frequencies*** for the floor and seat combinations.

Floor type Seat type (underpass) Eff. back rest* (cm) SDE calc.** (Hz) SDE meas.*** (Hz)
Flat Closed (0 cm) 88 98 94–110
Open (10 cm) 78 111 122–149
Open (24 cm) 64 135 149–158
Mod. raked Closed (0 cm) 78 111 94–99
Open (10 cm) 78 111 109–111
Open (24 cm) 64 135 145–158
Steeply raked Closed (0 cm) 64 135 97–102
Open (10 cm) 64 135 97–102
Open (24 cm) 64 135 109–115

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.