Open Access
Issue
Acta Acust.
Volume 5, 2021
Article Number 4
Number of page(s) 10
Section Hearing, Audiology and Psychoacoustics
DOI https://doi.org/10.1051/aacus/2020029
Published online 23 December 2020

© H. Joost et al., Published by EDP Sciences, 2020

Licence Creative CommonsThis is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

1 Introduction

In the light of a steadily increasing number of reports on infrasound exposure, it is important to understand how humans perceive infrasound, which is defined as sound with frequencies below 20 Hz [1]. Several studies indicate that the human auditory system is sensitive to infrasound down to at least 2 Hz (e.g., [24]; for a review, see [5]). They show that an auditory detection threshold can be determined also for infrasound stimuli, provided that they have sufficiently high Sound Pressure Levels (SPLs). Recent studies on human brain activation [68] show that the brain responds to infrasound that is being presented to the ear, at threshold and at higher loudness levels. Two of them [7, 8] show an activation of the primary auditory cortex. This further supports the view that infrasound is processed by the auditory system. Until now, however, the mechanisms underlying this auditory infrasound perception have not yet been fully understood.

A hypothesis is that non-linear processes within the ear generate distortion products, in the following referred to as ear-generated distortion products, that contribute to the perception of infrasound [3]. The high SPLs required to perceive infrasound may generate such distortion products by means of a number of mechanisms: For instance, elastic structures of the ear may be driven outside their linear range to such an extent that higher harmonics are generated. The non-harmonic displacement of the eardrum would produce measurable distortion products in the ear canal. Furthermore, non-linear behavior of middle-ear structures could also generate distortion products in the ear canal. In general, distortion products in the audio-frequency range that have SPLs above the listeners’ individual thresholds could contribute to infrasound perception. A different mechanism is that distortion products are generated within the cochlea, e.g., by active outer hair cell motility, and transmitted back to the ear canal where they can be measured like Otoacoustic Emissions (OAEs, [9]). Distortion products generated in this way could contribute to infrasound perception even if the SPLs in the ear canal were well below the listeners’ individual thresholds, since these distortion products are attenuated on their way from the cochlea to the ear canal. The existence of audio-frequency ear-generated distortion products may also explain the recent finding that simultaneously presented audio sound increases thresholds of infrasound [10]: Audio sound might, at least partially, mask ear-generated distortion products.

The aim of the present study was to test the hypothesis of audible ear-generated distortion products by examining the sound field in the human ear canal for higher harmonic distortions during the stimulation with supra-threshold pure-tone infrasound. To this end, a custom-made Low-Distortion Sound Reproduction System (LDREPS) was used for presenting the stimuli and recording the sound in the ear canal [11]. Since this study focused on the perception of infrasound by the auditory system, stimuli were delivered exclusively to the ear canal by means of the LDREPS ear insert. To avoid false positive results when analyzing the presence of ear-generated distortion products, it is mandatory that both, the infrasound presentation system and the ear-canal sound recording system, do not generate pronounced harmonic distortions, in the following referred to as technical distortions. These were determined in an occluded-ear simulator prior to the measurements in human ear canals. In each of the listeners, also the SPLs at the behavioral detection thresholds in quiet for the infrasound stimuli were determined. For simplicity, these will be referred to as thresholds in the following. They were compared to literature data ([5] for infrasound frequencies; [12] for audio frequencies), which will be referred to as reference thresholds in the following. To test a possible contribution of distortion products to infrasound detection, the thresholds were related to the analysis of the sound field in the ear canal and to the physiological background noise therein.

2 Methods

2.1 The Low-Distortion Sound Reproduction System (LDREPS)

Figure 1 shows key parts of the sound reproduction system, LDREPS. In the top of the figure, there are two commercially available RadioEar DD45 audiometric earphone transducers (RadioEar, Denmark), which are mounted in air-sealed aluminum housings, each with a sound outlet in the front plate. Sound tubes with a length of 25 cm connect the sound outlets to the ear insert of an Etymotic ER-10B+ low-noise microphone system (Etymotic Research Inc., USA, bottom of the figure). The volume that is enclosed by the membrane of the earphone transducers, the tubes, and the ear is so small that it acts as a pressure chamber for low frequencies, enabling acoustic stimulation with the DD45 earphone transducers down to infrasound frequencies. The LDREPS was designed with two DD45 transducers to allow the user to transmit audio-sound and infrasound stimuli via separate channels. Since the present study was only using pure-tone infrasound signals, only one of the transducers was driven. Still, the second DD45 cartridge was acoustically connected, since it constitutes an integral part of the acoustically characterized LDREPS. The DD45 transducer was driven by a custom-made dual-channel headphone amplifier, based on an LPA-2S board (Funk Tonstudiotechnik, Germany). The board was modified by the manufacturer for the special purpose of driving the low-impedance (10 Ω) headphone transducer down to 2 Hz with a maximum power of 500 mW. This headphone amplifier offers high output power combined with low noise and minimum harmonic distortion (THD + N: 1 kHz signal 0.0013%; 10 Hz signal 0.0006%; both at 500 mW/10 Ω).

thumbnail Figure 1

Picture of the two DD45 earphone transducers (top) coupled with the Etymotic ER-10B+ system (bottom) via two tubes, as part of the LDREPS.

The LDREPS was specially developed for presenting signals with very low distortion in the frequency range from 4 Hz to 4 kHz and for SPLs that are equivalent to a loudness level of 40 phon. The system used in the present study was a slightly modified version of the one described in [11]: A low-pass filter (second order, -3 dB cutoff frequency: 30 Hz) was inserted in the signal path between amplifier and transducer for safety reasons, ensuring that high SPLs can be presented in the infrasound range while the levels in the audio-frequency range are limited. This modified version was already used to measure the effect of number of spectral components on the infrasound detection threshold [13].

2.2 Analysis of technical distortions

To ensure that potential distortion products in the ear canal are not generated by the LDREPS itself, it is crucial to first quantify the technical distortions of the system. These were determined using the setup shown in Figure 2. The infrasound emitted from the DD45 earphone transducer was guided through a sound tube to the Etymotic ER-10B+ ear insert. The ear insert was connected to a B&K 4157 occluded-ear simulator (Brüel & Kjær, Denmark) by means of the adapter DB-2012, which simulates the external ear canal. The Etymotic ER-10B+ microphone measured the sound in the occluded-ear simulator. The microphone signal was amplified by the dedicated microphone preamplifier and was then forwarded to one channel of the APx555 audio analyzer (Audio Precision, USA). The APx555 audio analyzer also provided the pure-tone test signals, which were fed into the earphone amplifier Funk LPA-2S driving the DD45 transducer through a custom-built low-pass filter.

thumbnail Figure 2

Block diagram of the setup for measuring technical distortions of the LDREPS. Red and gray connecting lines highlight the parts that were used in the present study. The second channel (light blue connecting lines) enables the LDREPS to present an additional audio-sound stimulus (not used in this study).

The DD45 earphone transducers, the Etymotic ER-10B+ ear insert, and the B&K 4157 occluded-ear simulator were placed in a double-walled sound-insulated booth. The ER-10B+ microphone was calibrated using the ear simulator as a reference (see [11]). It was not overloaded by the high infrasound pressure levels and, at the same time, showed enough sensitivity and sufficiently low noise to measure distortion products for both, infrasound and audio sound, while high-level infrasound was present (see Fig. 1 in [11]). Magnitude spectra were measured in silence and for pure tones with frequencies of 4, 8, 12, and 16 Hz. The recorded signal was analyzed by the APx555 audio analyzer, which calculated magnitude spectra in blocks of about 20 s with a resolution of 46 mHz using a flat-top window. The spectra were then averaged. Each panel of Figure 3 shows an averaged spectrum (average of five; orange solid lines) of the signal that was recorded in the B&K 4157 occluded-ear simulator by means of the ER-10B+ microphone. In each panel, the frequency spectrum is limited to the frequency range from 3 Hz to 300 Hz. The SPLs of the pure-tone signals were 120 dB for the 4 Hz tone, 111 dB for 8 Hz, 106 dB for 12 Hz, and 103 dB for 16 Hz. They corresponded to loudness levels that were slightly below 40 phon (see [5]). Even at the SPLs used in the present study, the levels of the technical distortions were at least 20 dB below the reference thresholds (dashed lines in Fig. 3). Note that these distortions were more prominent than those shown in [11]. This is due to the additional non-linearity of the low-pass filter that was inserted in the signal path.

thumbnail Figure 3

Magnitude spectra (orange solid lines) produced by the LDREPS in the occluded-ear simulator and measured with the ER-10B+ microphone. Each panel shows the averaged spectrum for a pure-tone signal at a level above its reference threshold. The signal frequency, f1, is indicated in the bottom left corner of the panel. For comparison, the spectrum of a background noise measurement is also shown (dark gray solid line). In addition, the reference thresholds are shown as a black dashed line. The frequency spectra are limited to the frequency range from 3 Hz to 300 Hz.

2.3 Measurement of ear-generated distortion products

The stimuli and the setup were essentially the same as the one used to measure technical distortions of the LDREPS (see Fig. 2) with the only difference that the ER10B+ ear insert was positioned in the left ear canal of the listener, instead of in the occluded-ear simulator. The listeners were seated in a double-walled sound-insulated booth. The signal in the ear canal was recorded by means of the ER-10B+ microphone in silence and for pure tones with frequencies of 4, 8, 12, and 16 Hz. To reduce interference by body-borne noise in the recorded signal, listeners were asked to suspend their deglutition and masticatory movements as much as possible, and to avoid any unnecessary motion during the two-minute measurement phases. As for the analysis of the technical distortions, the recorded signal was analyzed by the APx555 audio analyzer, which calculated averaged magnitude spectra with a resolution of 46 mHz. If a magnitude spectrum was interfered by unwanted noises, it was discarded, and the measurement was repeated to get the specified number of averages for the spectrum. During each measurement, the proper fit of the ear insert was controlled in-situ by the level of the fundamental.

2.4 Measurement of thresholds

Thresholds were measured for pure tones with frequencies of 4, 8, 12, and 16 Hz in the same ear in which the sound was recorded with the high-sensitivity ER-10B+ microphone during supra-threshold infrasound presentation. As in [4] and [13], the duration of the ramps and total duration of the signals (including raised cosine on- and offset ramps) depended on frequency (see second and third column of Tab. 1).

Table 1

Parameters of stimuli used for threshold measurements.

A three-interval, three-alternative forced-choice procedure with a one-up two-down rule was used, which leads to a detectability at threshold of 70.7% [14]. The intervals of a trial were separated by 250 ms of silence. During the presentation of a trial, the timings of the intervals were highlighted on a screen, which was positioned in front of the listener. One randomly chosen interval contained the signal.

The listener was requested to press a key on a hand-held keyboard to indicate which of the intervals contained the signal. The adaptive procedure started at an SPL that corresponded to a loudness level of ~20 phon (see [5]). The starting SPLs (in dB) are shown in the fourth column of Table 1. The initial step size was 4 dB and was halved after each upper reversal until the final step size of 1 dB was reached. The run continued with the final step size for four reversals. The mean value of the SPLs at these four reversals was taken as a threshold estimate. For each of the four pure-tone stimuli, thresholds were measured twice. The mean value of these two threshold estimates was taken as the final threshold estimate.

The adaptive procedure was controlled by a MATLAB program. All signals were generated with a sampling rate of 96 kHz and a resolution of 24 bits. The digital signals were converted to analog signals via an external sound card (RME Fireface, Haimhausen, Germany) and presented to the ear through the LDREPS. To spot-check the proper fit of the ear insert, the sound pressure levels of the pure-tone signals, which had been calibrated in a B&K 4157 occluded-ear simulator (Brüel & Kjær, Denmark), were measured in-situ by means of the ER-10B+ microphone prior to or after the listening tests. Before the actual threshold measurements, listeners had a short practice run with a 16 Hz stimulus to familiarize with the experiment, in which communication with the experimenter was possible.

The thresholds of the listeners were subdivided into groups based on the presence or absence of distortions. Differences between median thresholds of these groups were quantified using the nonparametric two-sided Wilcoxon rank-sum test. The significance level was set to α = 0.05.

2.5 Listeners

Sixteen listeners (9 female, 7 male) between 19 and 33 years (median = 22 years) participated in the experiments. All were paid volunteers. Prior to the experiment, the functionality of their hearing was tested. Their audiometric hearing levels of the ear that was used for the infrasound experiment were lower than or equal to 15 dB for all audiometric frequencies between 125 Hz and 4 kHz. All participants were otologically normal as confirmed by a questionnaire for hearing testing (Annex A of ISO 389-9 [15]) and by otoscopic examination. They were instructed on the goal of the study and on the anonymized usage of their data according to the General Data Protection Regulation (GDPR) of the European Union. The Declaration of Helsinki was adhered to in all our measurements. Approval was obtained from the local ethics committee (Medical faculty of the Otto von Guericke University Magdeburg, ethics application 79/17).

3 Results

3.1 Ear-generated distortion products

Figure 4 shows examples of magnitude spectra recorded in the ears of four listeners (green solid lines). Each panel shows the result for a 4 Hz signal of one listener and the corresponding spectrum measured in the B&K 4157 occluded-ear simulator (black solid lines). Since in the experiment two realizations of the low-pass filter were used, the spectrum was not the same for all listeners. In each panel, the frequency spectra are limited to the frequency range from 2 Hz to 38 Hz. The background noise levels in the listeners’ ears are higher than the background noise levels in the ear simulator.

thumbnail Figure 4

Magnitude spectra for a 4 Hz infrasound, measured with the low-noise ER-10B+ microphone, in the ear canal of four listeners (green solid lines) and the corresponding spectra in the B&K 4157 occluded-ear simulator (black solid lines). Each panel shows the result of one listener. In all panels, the spectra are limited to the frequency range from 2 Hz to 38 Hz. The reference thresholds are shown as a black dashed line, the individual thresholds as red crosses. Black arrows indicate ear-generated distortion products, which were identified by means of criteria described in the text (see also Fig. 5).

The average spectra of all listeners were analyzed with respect to peaks at the higher harmonic frequencies f2 to f9 of the respective signal frequency f1. Since the spectra were noisy, a criterion had to be defined to distinguish an ear-generated peak at a higher harmonic frequency from a random fluctuation of the power spectral density. In addition, it was necessary to ensure that the peak did not represent just a technical distortion component, which led to a second criterion. Figure 5 visualizes the two criteria that were used to detect an ear-generated distortion product. It shows a section of the spectrum of the 4 Hz signal measured in the ear of example listener L8 (whose 4 Hz spectrum is also shown in the bottom left corner of Fig. 4).

thumbnail Figure 5

Example magnitude spectra to visualize the criteria for the detection of ear-generated distortions. To this end, a portion of the spectra of the bottom left panel of Figure 4 is redrawn. The dark gray boxes indicate the 0.4 Hz wide frequency bands around the higher harmonics that were used to derive their power spectral densities. The light gray boxes indicate the 2.4 Hz wide frequency bands around the higher harmonic that were used to estimate the power spectral density of the noise. From these two quantities, a tone-to-noise ratio was calculated and expressed as a level difference ΔLtn. In addition, the ratio between the power in the narrow frequency band around the higher harmonics between the spectrum recorded in the listener’s ear and that recorded in the occluded-ear simulator was computed and expressed as a level difference ΔLtt,s. Based on these measures, it was decided whether an ear-generated distortion product is present (indicated by the black arrow) or not (see text for details).

Both criteria are based on ratios of power spectral densities. The first criterion calculates the ratio between the tone and surrounding-noise power spectral densities (cf. [16], Eq. (1)). To assess the power density of the tone, the power is determined in a narrow band around its harmonic frequency. The width of the band is Δft = 0.4 Hz. This is shown in Figure 5 for the higher harmonic frequencies 8 Hz, 12 Hz, and 16 Hz with dark gray areas. Since in real-world settings, this frequency band contains the tone and the background noise (see [16]), the respective power will be referred to as Pt+n (t+n for tone and noise) in the following. The power spectral density is then(1).

The power spectral density of the surrounding noise is determined in a wider frequency band with a bandwidth Δftot = 2.4 Hz. To get an estimate of the power of this surrounding noise (i.e., in the light gray areas of Fig. 5), the difference between the total power Ptot in this wider band and Pt+n was calculated. The power spectral density ϱn of the surrounding noise is then (2).

To be classified as a peak, the ratio of these two power spectral densities should be at least two. When expressed as a level difference ΔLtn, this is equivalent to(3).

This criterion was applied to the higher harmonics f2 to f9 of the signal frequency f1.

The second criterion compares the spectrum in the ear canal with the spectrum in the occluded-ear simulator. For both spectra, the power spectral densities in the narrow frequency band (Δft = 0.4 Hz) around the higher harmonic frequency were determined. The ratio of these two quantities should be at least two. As a level difference ΔLtt,s, this is equivalent to(4), where Pt+n,s is the power in the narrow band around the higher harmonic frequency for the occluded-ear simulator, indicated by the additional subscript “s”. Only if both criteria were fulfilled, the distortion component was classified as being an ear-generated distortion product.

Regarding the example shown in Figure 5, for the 8 Hz component, ΔLtn is 11.0 dB (> 3 dB) and ΔLtt,s is 4.9 dB (> 3 dB). Hence, this component is, according to the criteria of the present study, an ear-generated distortion product. The 12 Hz component fulfills the first criterion (ΔLtn = 10.1 dB > 3 dB), but not the second one (ΔLtt,s = 2.6 dB <3 dB). The 16 Hz component does not fulfill the first criterion (ΔLtn = 0.7 dB < 3 dB), but fulfills the second one (ΔLtt,s = 5.9 dB >3 dB).

When these criteria are applied to the example spectra shown in Figure 4, ear-generated distortion products are detected in three cases as indicated by black arrows above the corresponding distortion frequencies. Two were found for listener L9 (top row, left column) at the harmonics f3 and f5; one was found for listener L8 (bottom row, left column) at the harmonic f2. Listeners L4 and L6 (right column) had no ear-generated distortion products for the 4 Hz signal frequency. The SPLs of the three distortion products of L8 and L9 are well below those of the reference thresholds (black dashed lines in Fig. 4).

In all listeners, ear-generated distortion products were detected for at least one of the four infrasound frequencies. However, the occurrence of these distortions was not equally distributed across the four infrasound frequencies, as shown in Table 2. The table lists, for each of the four signal frequencies, f1, the number of ear-generated distortion products found at the higher harmonics f2 to f9. Of all 16 × 4 × 8 = 512 possibilities of observing an ear-generated distortion product, only 51 (i.e., less than 10 %) turned out to be true findings according to the criteria. Almost all had harmonic numbers between 2 and 5; only one was detected at the sixth harmonic of the 16 Hz signal and another one at the eighth harmonic of the 8 Hz signal. Most (n = 34) ear-generated distortion products were found for the 4 Hz and the 8 Hz signals. Seventeen of these were in the infrasound range (gray background in Tab. 2), and they belong exclusively to the 4 Hz signal. They are opposed to only three ear-generated distortions at the fifth harmonic of the 4 Hz signal, i.e., in the audio-frequency range. In general, distortion product levels were well below reference thresholds (at least 10 dB) for all signal frequencies and all listeners.

Table 2

Number of ear-generated distortion products found at the higher harmonics f2 to f9 of the signal frequency f1, based on 16 individual measurements of the magnitude spectrum per frequency. Harmonics in the infrasound range are indicated in bold font.

3.2 Correlation between thresholds and ear-generated distortion products

Panel A of Figure 6 shows the mean SPL at threshold as a function of pure-tone frequency for each of the 16 listeners (gray dotted-dashed lines). Superimposed are the grand median (green circles) and the corresponding interquartile range (green semi-transparent area). Thresholds decrease monotonically from 112.8 dB at 4 Hz to 86.6 dB at 16 Hz. Panel B of Figure 6 compares the grand median thresholds of this study with data from the literature (see Discussion section).

thumbnail Figure 6

Threshold levels for infrasound stimuli. Panel A: Data for pure-tone infrasound stimuli. Green circles and the green semi-transparent area show the median sound pressure level at threshold in dB and the corresponding interquartile range, respectively, across all 16 listeners. Gray dotted-dashed lines indicate individual thresholds; the slightly darker and thicker lines indicate thresholds of those three listeners, who had most ear-generated distortion products (see text). Panel B: The green circles are a reproduction of the median thresholds in Panel A. The gray solid line indicates the 2nd-order regression of reference thresholds reported in Figure 10 of [5]. The boxes represent threshold values reported in [4]. Crosses indicate pure-tone thresholds published in [13]; five out of their 14 listeners also participated in the present study.

To test the hypothesis of a possible contribution of distortions to infrasound detection, the threshold data of the 16 listeners were separated for each frequency according to the absence and the presence of ear-generated distortion products at any higher harmonic from f2 to f9 of the signal frequency f1.

Panel A of Figure 7 shows those individual thresholds, where no ear-generated distortion products were measured, with filled blue downward-pointing triangles. In addition, the median thresholds of this group are shown with open blue downward-pointing triangles connected with a solid blue line. The interquartile range is indicated by a semi-transparent light blue area. Panel B of Figure 7 shows the individual thresholds where ear-generated distortion products were detected with filled orange upward-pointing triangles and the median thresholds of this group are shown with open orange downward-pointing triangles connected with a solid orange line; the interquartile range is indicated by a semi-transparent light orange area. For comparison, each panel also shows the median thresholds of the other group (with the corresponding symbol and connected with a dashed line).

thumbnail Figure 7

Sound pressure levels at threshold for pure-tone infrasound stimuli. The threshold data of the 16 listeners were separated according to the absence (blue, downward-pointing triangles) and presence (red, upward-pointing triangles) of ear-generated distortion products at any higher harmonic from f2 to f9 of the signal frequency f1. Open triangles indicate the median thresholds for the two groups of listeners. Semi-transparent areas indicate the corresponding inter-quartile ranges for those with distortion products (Panel B) and those without (Panel A).

The largest level difference between the two medians is observed at 4 Hz. At this frequency, the median threshold for the listeners without distortions was 2.4 dB lower than the median threshold for those listeners where no distortions were detected. This difference is not significant (Wilcoxon rank-sum test with p > 0.8 and W = 32). The differences at the other three frequencies are considerably smaller (0.1 dB at 8 Hz and 12 Hz, and 0.8 dB at 16 Hz; each Wilcoxon rank-sum test with p > 0.7 and W > 35).

Figure 8 compares the individual thresholds with the individual noise levels in quiet. The panels show the threshold as a function of background noise for each of the four signal frequencies, f1. The noise level was calculated for the infrasound-frequency range from 2 Hz to 20 Hz only, but the results do not change when the range is extended to low audio frequencies (not shown). There is a strong overlap between the data points for the group of thresholds with ear-generated distortion products (red, upward-pointing triangles) and those without ear-generated distortion products (blue, downward-pointing triangles).

thumbnail Figure 8

Analysis of correlations between infrasound thresholds and physiological infrasound noise in the ear canal. Each panel shows the analysis for one of the four infrasound frequencies. Each triangle represents the data of one of the 16 listeners. Colors and symbols indicate the absence (blue, downward-pointing triangles) or presence (red, upward-pointing triangles) of ear-generated distortion products at any higher harmonic from f2 to f9 of the signal frequency f1. To quantify physiological infrasound noise, the average spectrum (average of five) was measured in quiet and integrated from 2 Hz to 20 Hz. The integrated power is expressed in dB.

4 Discussion

The aim of the present study was to test the hypothesis that audible ear-generated distortion products are involved in infrasound perception. A custom-made low-distortion sound reproduction system, LDREPS [11], was used to detect ear-generated distortion products in the ear canal and to measure infrasound thresholds in quiet. In all listeners, ear-generated distortion products were detected for at least one of the four infrasound frequencies, indicating a non-linear response to these infrasound stimuli, but their levels were well below reference thresholds. Note that, at this point, it is unclear, which mechanism causes the ear-generated distortion products for the infrasound stimuli. This contrasts to otoacoustic emissions (OAEs, [9]), where it is commonly assumed that their origin is an active process within the cochlea (e.g., [17]). A key part for OAEs seems to be that sound is propagating backwards from the cochlea to the ear canal, where it is then finally recorded. For infrasound, the origin could still be in the cochlea; but it is also possible that, due to the high SPLs, non-linear properties of other parts of the ear, such as the middle ear, or the eardrum, play a role. The level measured in the ear canal may differ from that acting in the inner ear. Thus, levels of distortion products below threshold may not necessarily be seen as evidence against the hypothesis of infrasound detection through audible distortion products, at least if they are not generated in the outer ear. If the source of the measured distortions was solely the outer ear, they would be inaudible, since their levels were well below threshold.

To test a possible contribution of distortion products to infrasound detection, the thresholds were related to the analysis of the sound field in the ear canal. The grand median thresholds of this study (measured with LDREPS) are similar to thresholds reported in the literature (measured with other setups). The maximum deviation between the different data sets shown in Panel B of Figure 6 is 3 dB, i.e., well within the interquartile range of the present data (Panel A of Fig. 6).

In general, the data did not support the hypothesis of ear-generated distortions contributing to infrasound perception. The listeners with ear-generated distortion products for a specific frequency did not have lower thresholds than those without (see Fig. 7). The 4 Hz thresholds for listeners with distortion products for this signal frequency were even slightly higher than those for listeners without distortions, although the difference was not significant. For all other frequencies, thresholds for listeners with distortion products were about the same as those for listeners without distortion products. Thus, the presence of ear-generated distortion products seems to have no clear impact on pure-tone thresholds of infrasound stimuli in quiet. This could have already been expected on the basis of the individual data shown in Figure 4. The two listeners in the top panels had very high thresholds and the two listeners in the bottom panel had very low thresholds. In each group of listeners, one did have ear-generated distortions and one did not.

The two example listeners of Figure 4 not showing ear-generated distortion products had higher physiological noise than the two showing ear-generated distortion products. Thus, one may hypothesize that ear-generated distortion products were only detected when the physiological noise was low. To test this hypothesis and answer the question if infrasound thresholds are determined by the physiological background noise, the individual thresholds were compared to the individual noise levels in quiet (see Fig. 8). This analysis indicated that thresholds do not correlate with physiological background noise: For all signal frequencies, the absolute value of the Pearson correlation coefficient, R, is low (|R| < 0.3). Thus, ear-generated distortion products are detected not only in listeners with low levels of physiological noise.

Considering the absence of correlation between distortion products, thresholds, and physiological noise, the present data suggest that distortion products may not play a key role in infrasound perception. This is also supported by a recent publication of Marquardt and Jurado [18]. They found that it is difficult to distinguish an amplitude-modulated tone from a tone with an additional infrasound, indicating that infrasound is perceived as modulation. Since there is always a certain residual background noise in the ear (due to, e.g., blood flow), one may, e.g., argue that infrasound is always perceived as modulation (of this residual noise when the infrasound is presented in quiet).

5 Conclusions

The present study used a low-distortion sound reproduction system to detect ear-generated distortion products in the ear canal for infrasound pure-tone stimuli at supra-threshold SPLs. Ear-generated distortion products were detected in all of the listeners for at least one of the signal frequencies, indicating a non-linear response to these infrasound stimuli. However, the SPLs of the ear-generated distortion products were considerably lower than the reference threshold levels for their frequencies (more than 10 dB). In addition, thresholds of listeners with ear-generated distortion products for a specific frequency did not have lower thresholds than those without distortions for this frequency. These findings suggest that higher harmonics do not provide detection cues for infrasound pure tones.

Acknowledgments

The project was supported by the Deutsche Forschungsgemeinschaft (DFG, projects FE 1192/3-1 and VE 373/4-1). Special thanks go to all the listeners who participated in the experiment.

References

  1. ISO 7196:1995: Acoustics – Frequency-weighting characteristic for infrasound measurements. International Organization for Standardization, Geneva. https://www.iso.org/obp/ui/es/#iso:std:iso:7196:ed-1:v1:en. [Google Scholar]
  2. N.S. Yeowart, M.J. Evans: Thresholds of audibility for very low-frequency pure tones. Journal of the Acoustical Society of America 55, 4 (1974) 814–818. [CrossRef] [Google Scholar]
  3. G. Békésy: Über die Hörschwelle und Fühlgrenze langsamer sinusförmiger Luftdruck schwankungen. (On the hearing threshold and the sensation limit of sinusoidal air pressure fluctuations). Annalen der Physik 26, 5 (1936) 554–566. [Google Scholar]
  4. R. Kühler, T. Fedtke, J. Hensel: Infrasonic and low-frequency insert earphone hearing threshold. Journal of the Acoustical Society of America 137 (2015) EL347–EL353. [CrossRef] [PubMed] [Google Scholar]
  5. H. Møller, C.S. Pedersen: Hearing at low and infrasonic frequencies. Noise Health 6 (2004) 37–57. [Google Scholar]
  6. O. Behler, S. Uppenkamp: Activation in human auditory cortex in relation to the loudness and unpleasantness of low-frequency and infrasound stimuli. Plos One 15 (2020) e0229088. https://doi.org/10.1371/journal.pone.0229088. [Google Scholar]
  7. C. Jurado, T. Marquardt: Brain’s frequency following responses to low-frequency and infrasound. Archives Acoustics 45 (2020) 313–319. [Google Scholar]
  8. M. Weichenberger, R. Kühler, M. Bauer, J. Hensel, R. Brühl, A. Ihlenfeld, B. Ittermann, J. Gallinat, C. Koch, T. Sander, S. Kühn: Brief bursts of infrasound may improve cognitive function – An fMRI study. Hearing Research 328 (2015) 87–93. [CrossRef] [PubMed] [Google Scholar]
  9. D.T. Kemp: Stimulated acoustic emissions from within the human auditory system. Journal of the Acoustical Society of America 64 (1978) 1386–1391. [CrossRef] [Google Scholar]
  10. E. Burke, J. Hensel, T. Fedtke, S. Uppenkamp, C. Koch: Detection thresholds for combined infrasound and audio-frequency stimuli. Acta Acustica united with Acustica 105 (2019) 1173–1182. [CrossRef] [Google Scholar]
  11. H. Joost, B. Friedrich, J.L. Verhey, T. Fedtke: How to present pure-tone infrasound to the ear. Proceedings of the 23rd International Congress on Acoustics, Aachen, 2019, pp. 1470–1477. http://pub.dega-akustik.de/ICA2019/data/articles/000733.pdf. [Google Scholar]
  12. ISO 389–7:1996: Acoustics – Reference zero for the calibration of audiometric equipment – Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions. International Organization for Standardization, Geneva. [Google Scholar]
  13. B. Friedrich, H. Joost, T. Fedtke, J.L. Verhey: Spectral integration of infrasound at threshold. Journal of the Acoustical Society of America 147 (2020) EL259–EL263. [CrossRef] [Google Scholar]
  14. H. Levitt: Transformed up-down methods in psychoacoustics. Journal of the Acoustical Society of America 49 (1971) 467–477. [CrossRef] [Google Scholar]
  15. ISO 389–9:2009: Acoustics – Reference zero for the calibration of audiometric equipment – Part 9: Preferred test conditions for the determination of reference hearing threshold levels. International Organization for Standardization, Geneva. [Google Scholar]
  16. R.A. Dobie, M.J. Wilson: A comparison of t test, F test, and coherence methods of detecting steady-state auditory-evoked potentials, distortion-product otoacoustic emissions, or other sinusoids. Journal of the Acoustical Society of America 100 (1996) 2236–2246. [CrossRef] [Google Scholar]
  17. D.T. Kemp: Otoacoustic emissions, travelling waves and cochlear mechanisms. Hearing Research 22 (1986) 95–104. [CrossRef] [PubMed] [Google Scholar]
  18. T. Marquardt, C. Jurado: Amplitude modulation may be confused with infrasound. Acta Acustica united with Acustica 104 (2018) 825–829. [CrossRef] [Google Scholar]

Cite this article as: Joost H, Friedrich B, Verhey JL & Fedtke T. 2021. Is infrasound perceived by the auditory system through distortions? Acta Acustica, 5, 4.

All Tables

Table 1

Parameters of stimuli used for threshold measurements.

Table 2

Number of ear-generated distortion products found at the higher harmonics f2 to f9 of the signal frequency f1, based on 16 individual measurements of the magnitude spectrum per frequency. Harmonics in the infrasound range are indicated in bold font.

All Figures

thumbnail Figure 1

Picture of the two DD45 earphone transducers (top) coupled with the Etymotic ER-10B+ system (bottom) via two tubes, as part of the LDREPS.

In the text
thumbnail Figure 2

Block diagram of the setup for measuring technical distortions of the LDREPS. Red and gray connecting lines highlight the parts that were used in the present study. The second channel (light blue connecting lines) enables the LDREPS to present an additional audio-sound stimulus (not used in this study).

In the text
thumbnail Figure 3

Magnitude spectra (orange solid lines) produced by the LDREPS in the occluded-ear simulator and measured with the ER-10B+ microphone. Each panel shows the averaged spectrum for a pure-tone signal at a level above its reference threshold. The signal frequency, f1, is indicated in the bottom left corner of the panel. For comparison, the spectrum of a background noise measurement is also shown (dark gray solid line). In addition, the reference thresholds are shown as a black dashed line. The frequency spectra are limited to the frequency range from 3 Hz to 300 Hz.

In the text
thumbnail Figure 4

Magnitude spectra for a 4 Hz infrasound, measured with the low-noise ER-10B+ microphone, in the ear canal of four listeners (green solid lines) and the corresponding spectra in the B&K 4157 occluded-ear simulator (black solid lines). Each panel shows the result of one listener. In all panels, the spectra are limited to the frequency range from 2 Hz to 38 Hz. The reference thresholds are shown as a black dashed line, the individual thresholds as red crosses. Black arrows indicate ear-generated distortion products, which were identified by means of criteria described in the text (see also Fig. 5).

In the text
thumbnail Figure 5

Example magnitude spectra to visualize the criteria for the detection of ear-generated distortions. To this end, a portion of the spectra of the bottom left panel of Figure 4 is redrawn. The dark gray boxes indicate the 0.4 Hz wide frequency bands around the higher harmonics that were used to derive their power spectral densities. The light gray boxes indicate the 2.4 Hz wide frequency bands around the higher harmonic that were used to estimate the power spectral density of the noise. From these two quantities, a tone-to-noise ratio was calculated and expressed as a level difference ΔLtn. In addition, the ratio between the power in the narrow frequency band around the higher harmonics between the spectrum recorded in the listener’s ear and that recorded in the occluded-ear simulator was computed and expressed as a level difference ΔLtt,s. Based on these measures, it was decided whether an ear-generated distortion product is present (indicated by the black arrow) or not (see text for details).

In the text
thumbnail Figure 6

Threshold levels for infrasound stimuli. Panel A: Data for pure-tone infrasound stimuli. Green circles and the green semi-transparent area show the median sound pressure level at threshold in dB and the corresponding interquartile range, respectively, across all 16 listeners. Gray dotted-dashed lines indicate individual thresholds; the slightly darker and thicker lines indicate thresholds of those three listeners, who had most ear-generated distortion products (see text). Panel B: The green circles are a reproduction of the median thresholds in Panel A. The gray solid line indicates the 2nd-order regression of reference thresholds reported in Figure 10 of [5]. The boxes represent threshold values reported in [4]. Crosses indicate pure-tone thresholds published in [13]; five out of their 14 listeners also participated in the present study.

In the text
thumbnail Figure 7

Sound pressure levels at threshold for pure-tone infrasound stimuli. The threshold data of the 16 listeners were separated according to the absence (blue, downward-pointing triangles) and presence (red, upward-pointing triangles) of ear-generated distortion products at any higher harmonic from f2 to f9 of the signal frequency f1. Open triangles indicate the median thresholds for the two groups of listeners. Semi-transparent areas indicate the corresponding inter-quartile ranges for those with distortion products (Panel B) and those without (Panel A).

In the text
thumbnail Figure 8

Analysis of correlations between infrasound thresholds and physiological infrasound noise in the ear canal. Each panel shows the analysis for one of the four infrasound frequencies. Each triangle represents the data of one of the 16 listeners. Colors and symbols indicate the absence (blue, downward-pointing triangles) or presence (red, upward-pointing triangles) of ear-generated distortion products at any higher harmonic from f2 to f9 of the signal frequency f1. To quantify physiological infrasound noise, the average spectrum (average of five) was measured in quiet and integrated from 2 Hz to 20 Hz. The integrated power is expressed in dB.

In the text

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.