Table 1
Summary of localization performance for the three HMD conditions detailing the Tukey-adjusted local angular metrics and localization reversal rates. Reported ± values for angular metrics are standard errors. Reported ± values for localization reversal rates are lower and upper 95% confidence intervals.
Condition | Local angular errors (°) |
Localization reversal rates (%) |
|||
---|---|---|---|---|---|
Great circle | Lateral | Weighted-polar | Front–back | Up–down | |
No HMD | 16.8 ± 0.9 | −2.0 ± 0.7 | 0.0 ± 0.7 | 4.3 [3.0, 6.1] | 1.5 [0.8, 2.9] |
Quest 2 | 17.6 ± 0.9 | −0.8 ± 0.7 | 0.6 ± 0.7 | 4.5 [3.1, 6.3] | 1.3 [0.7, 2.4] |
Hololens 1 | 17.7 ± 0.9 | −1.5 ± 0.7 | −0.2 ± 0.7 | 5.4 [3.8, 7.6] | 2.4 [1.3, 4.4] |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.