Open Access
Table 1
Main experimental results in terms of measured T30, EDT, C80, TS, STI values in octave bands. The values refer to sound source position S1 (see Fig. 3) and they have been averaged over all the receivers in the ottangulo, as it is the core of the present study (see Fig. 2). The standard deviations are provided in brackets.
125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | |
---|---|---|---|---|---|---|
T30 | 4.03 (±0.37) | 3.53 (±0.43) | 2.88 (±0.22) | 2.60 (±0.15) | 2.20 (±0.05) | 1.66 (±0.03) |
EDT | 3.07 (±0.27) | 2.96 (±0.26) | 2.60 (±0.24) | 2.40 (±0.14) | 2.10 (±0.07) | 1.52 (±0.05) |
C80 | −2.6 (±0.6) | −2.4 (±0.7) | −2.1 (±0.7) | −1.3 (±1.0) | −1.2 (±0.8) | 0.8 (±0.7) |
T S | 225 (±17) | 203 (±18) | 180 (±17) | 162 (±16) | 147 (±11) | 104 (±6) |
STI | 0.41 |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.