Open Access

Table A1

Parameters of the FDM simulation performed. All defined parameters are explained in [11].

Calculation end time t end 0.4 s
Time increment Δt 2 · 10−5  s
Grid parameter b 1.058
Local step size Δx 0.0545 m
Theoretical rail length (without boundaries) l 80 m
Number of boundary grid points n B 600
Force parameter σ 0.5 · 102 s
Force parameter a 0.7 · 10−4

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.