Table 25.

Impact of water storage and Bacillus subtilis attack on technical constants calculated from experimental data with ultrasonic velocity method [62].

Wood specimens Density Technical constants calculated with ultrasonic velocity method
Young moduli (108 N/m2) Shear moduli (108 N/m2)

Picea abies (kg/m3) EL ER ET GRT GLT GLR
Sound 407 86 13 3 1.80 6.63 7.92
Attacked 383 78 11 4 1.24 5.75 8.40
Difference % −6 −10 −13 +20 −31 −13 +6