Open Access

Table 1

Comparison of resonance frequencies of the flexible-plate resonator with different plate thicknesses using analytical model, finite-element model (FEM) and experiments.

tplate Analytical model f0
FEM
Experiment
Deviation
Clamped Simply-supported f0,FEM fmax
[mm] [Hz] [Hz] [Hz] [Hz] %
1 18 7.2 18 20 −11
2 49.1 20.2 48.8 37 24
3 88.2 37.0 87.9 57 35
4 130.1 56.6 128.9 76 41
10 293.9 189.6 217.1 122 43

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.