Open Access
Table 3
Results of the room acoustical measurements in the inner courtyard M for the eight measured source-receiver combinations in comparison to the corresponding simulated values.
Transmission path | S1-E1 | S1-E2 | S1-E3 | S1-E4 | S2-E1 | S2-E2 | S2-E3 | S2-E4 |
---|---|---|---|---|---|---|---|---|
T20 Meas. in s | 2.64 | 2.63 | 2.68 | 2.74 | 2.37 | 2.33 | 2.65 | 2.73 |
T20 Simul. in s | 2.64 | 2.57 | 2.73 | 2.66 | 2.49 | 2.39 | 2.65 | 2.57 |
T20 Difference in s | 0.00 | −0.06 | 0.05 | −0.08 | 0.12 | 0.06 | 0.00 | −0.16 |
T20 Difference in % | 0 | −2 | 2 | −3 | 5 | 3 | 0 | −6 |
EDT Meas. in s | 0.15 | 2.63 | 1.45 | 2.43 | 0.29 | 0.72 | 1.64 | 1.05 |
EDT Simul. in s | 0.27 | 2.61 | 2.84 | 2.78 | 0.49 | 0.88 | 3.88 | 1.92 |
EDT Difference in s | 0.12 | −0.02 | 1.39 | 0.35 | 0.20 | 0.16 | 2.24 | 0.87 |
EDT Difference in % | 80 | −1 | 96 | 14 | 69 | 22 | 137 | 83 |
G Meas. in dB | 10.3 | 3.1 | 8.9 | 2.5 | 11.5 | 10.7 | 7.8 | 6.7 |
G Simul. in dB | 7.6 | 0.9 | 6.1 | −0.8 | 8.4 | 8.3 | 4.0 | 5.0 |
G Difference in dB | −2.7 | −2.2 | −2.8 | −3.3 | −3.1 | −2.4 | −3.8 | −1.7 |
STI Meas. | 0.64 | 0.56 | 0.59 | 0.57 | 0.62 | 0.58 | 0.6 | 0.61 |
STI Simul. | 0.85 | 0.61 | 0.84 | 0.54 | 0.83 | 0.78 | 0.76 | 0.69 |
STI Difference | 0.21 | 0.05 | 0.25 | −0.03 | 0.21 | 0.20 | 0.16 | 0.08 |
EK Meas. | 0.77 | 0.71 | 0.73 | 0.63 | 0.62 | 0.63 | 0.64 | 0.55 |
EK Simul. | 0.74 | 1.07 | 0.74 | 0.62 | 0.57 | 0.55 | 0.64 | 0.75 |
EK Difference | −0.03 | 0.36 | 0.01 | −0.01 | −0.05 | −0.08 | −0.01 | 0.20 |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.