Table 1
Measured and derived properties for a Thomastik Infeld Dominant G cello string mounted on rigid supports. Values of the tension T and the frequency f0 were measured right after the first measurement session (Sect. 3.1). Three plucked-string signals were obtained by wire-breaking method after the measurement session to measure the bending stiffness B and the quality factor Q as a function of frequency (see Fig. 4).
Parameter | Value | Unit | Note |
---|---|---|---|
Tension T | 116.1 | N | Measured |
Scale length L | 0.7 | m | Measured |
Diameter d | 1.15 | mm | Measured |
Frequency f0 | 97.86 | Hz | Measured |
Linear density μ | 6.2 | g/m | μ = T/(2Lf0)2 |
Impedance Z | 0.849 | Kg/s |
![]() |
Bending stiffness B | 3.03 ± 0.015 | 10−4 N m2 | Measured |