Open Access

Table 12.

Optimal crossover frequencies, maximum absolute value of GD, E GD,Max, and ΔGD-SPL in the 40–120 Hz range across cases.

Crossover Max Freq. at
Case Freq. Abs. Max GD E GD,Max ΔGD-SPL
(Hz) GD (s) (Hz) (%) (dB)
1 120 0.137182 147.003 15.0 16.40
2 120 0.194066 234.537 38.6 15.43
3 110 0.535337 128.032 23.3 18.57
4 120 0.337217 132.717 53.5 19.48
5 60 0.536077 148.955 20.3 15.59
6 40 0.193026 133.078 0.0 11.41

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.