Open Access

Table 2.

Geometric parameters of reference, initial and optimized soundboards used in verification.

Soundboard designs
Parameters Unit SB1 ref SB1 init SB1 opt Error [%]
c 1 5.32309 5.32218 5.32294 0.017
c 2 – [10−3] −9.25953 −11.64148 −9.24901 0.114
c 3 – [10−2] −7.67400 −11.32463 −7.67646 −0.032
c 4 – [10−4] −1.22433 0.87117 −1.22456 −0.002
c 5 – [10−3] 1.39442 1.39442 1.40850 −1.001
c 6 – [10−6] −2.42384 0.56685 −2.39769 1.079
c 7 – [10−5] −4.54929 −2.37635 −4.54825 0.023
c 8 – [10−7] 1.34396 1.24914 1.34458 −0.046
c 9 – [10−6] 1.08591 0.98952 1.08553 0.035
L [mm] 504.825 497.540 504.822 0.001
h [mm] 3.00 2.50 3.00 0.000
R [mm] 49.213 49.213 49.219 −0.012