Open Access

Table 1.

Frequency-specific repeatability and significance metrics for ILD measurements across angles. RMS error derived from test-retest measurements (ATF with head shell, n = 2). Effect-to-error ratios (Eff/Err) correspond to the relation of mean absolute ILD difference (Fig. 6, right panel) to RMS error.

Frequency/ RMS Artificial Artificial
Hz error/ head vs. head vs.
/dB ATF ATF+head shell
(Eff/Err) (Eff/Err)
125 0.2 2.6 2.2
160 0.1 3.6 3.0
200 0.1 5.1 4.3
250 0.1 6.4 4.3
315 0.1 8.8 4.4
400 0.2 7.7 3.4
500 0.2 10.4 4.1
630 0.2 10.4 4.4
800 0.2 8.7 4.0
1000 0.3 6.8 2.8
1250 0.3 5.0 2.0
1600 0.3 3.4 3.7
2000 0.4 3.5 4.0
2500 0.5 2.6 3.0
3150 0.7 2.6 1.3
4000 0.6 4.1 2.1
5000 0.4 5.7 3.6
6300 0.4 5.6 3.5
8000 0.7 3.1 2.1
10000 0.7 3.6 2.2
Overall 0.4 4.0 2.4