Physical and technological parameters involved in creep model in model 1 of Table 3. Typical values are chosen in accordance with Table 3.1 from [17].

LabelDescriptionValueUnit
NC Wire turns 100 d.u.
AC Coil height 2 × 10−2 m
DC Coil diameter 2 × 10−2 m
τec Eddie-currents time 10−4 s
μ0 Vacuum permeability 4π10−7 H m−1
Air susceptibility 3.6 × 10−7 d.u.
Overhang in (24) 5 × 10−3 m
Shape in (24) 5 d.u.
αleak Leakage area ratio 10−2 d.u.
LP Path inductance LCLleak H
SG Air gap flux area πDCAC m2
SP Pole piece flux area SG m2
Sleak Leakage area (12) m2
ψM Magnet mmf (17) A
ϕss Steady-state flux Wb
Cleak Leakage capacity H
Lleak Leakage inductance Sect. 4.1 H