Issue |
Acta Acust.
Volume 5, 2021
|
|
---|---|---|
Article Number | 37 | |
Number of page(s) | 6 | |
Section | Audio Signal Processing and Transducers | |
DOI | https://doi.org/10.1051/aacus/2021032 | |
Published online | 26 August 2021 |
Technical & Applied Article
Microplasma microphones
Laboratoire d’Acoustique de l’Université du Mans, UMR CNRS 6613, 72085 Le Mans, France
* Corresponding author: philippe.bequin@univ-lemans.fr
Received:
24
January
2021
Accepted:
16
August
2021
It is shown experimentally that a microplasma created by a microstructured electrode array is sensitive to sound pressure. In this paper, two electrode architectures are used to create the microplasma. The sensitivity of these microplasma microphones, close to 0.4 nA/Pa, is estimated using a waveguide and a calibration method by comparison with a reference microphone. An empirical expression of the acoustic pressure sensitivity of microdischarges is proposed. The predictions of this empirical model are in good agreement with the experimental data.
Key words: Microplasma / Electric discharges / Transduction / Microphone / Acoustical measurements and instrumentation
© P. Béquin et al., Published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1 Introduction
An ionized gas or plasma is a mixture of electrons, ions and neutrals. In air, at atmospheric pressure, the plasma is generated by applying a DC voltage between two electrodes. In this DC discharge, the current flowing between the electrodes is carried by the free ions and electrons. DC discharges have been intensively studied over the last four decades in the context of medical sterilization, gas cleaning, air pollution control, biological decontamination, material processing, and aerodynamics [1–3]. However, the fine understanding of these discharges is not yet acquired, and there are still many unexplained or poorly modeled phenomena in these intrinsically complex gases.
In acoustics, the desired property is the coupling between a volume of plasma and the surrounding air. More particularly, the interactions between the charged particles and the neutral ones of the plasma and the surrounding gas. The variations in the electric current of the discharge cause pressure fluctuations and the propagation of a sound wave which is the principle of acoustic sources. Conversely, an acoustic wave passing through the plasma volume of a discharge provokes fluctuations in its electrical current which is the principle of acoustic sensors (acoustic pressure and acoustic particle velocity).
Among the acoustic sources using a plasma, the most familiar one is lightning [4]. The spark source is its miniaturized version used mainly in the fields of architectural and urban acoustics for acoustic measurements in scale models [5, 6]. The first acoustic studies on electric arcs began with Du Bois Duddell around the 1900s with the singing arcs [7, 8]. Since then, many acoustic sources using a plasma as an electroacoustic conversion element have emerged. The technical and theoretical developments associated with these sources are given in a review by Bastien in 1987 [9]. Since, other publications came to complete these studies: [10–12] (a non-exhaustive list of references).
In acoustics, the two useful quantities are acoustic pressure and acoustic particle velocity. Though these two quantities should be accessible to measurement by the use of a plasma discharge, there are very few studies considering this kind of measurement. The most recent one is that of Béquin et al. [13] which proposes a plasma velocimeter and an associated electroacoustic model. This work is based on previous studies by Lindvall [14] and Durbin et al. [15] on anemometers. For the measurement of acoustic pressure, only a few plasma microphones have been developed so far [16–23].
The content of this paper completes the experimental work of the same authors on microphonic devices using a plasma as sensing element [16]. In these plasma microphones (Fig. 1), the ionized gas is generated using negative point-to-plane discharges where a DC high negative voltage is applied to the needle electrode placed above a ground plane, metallic electrodes being separated by a millimetric or a sub-millimetric air gap (three-dimensional setup). The microphonic devices studied here use a microplasma array as an electroacoustic conversion element. Two electrodes configurations obtained by microfabrication techniques are used to generate the useful plasma [3, 24]. The electrode gap dimensions in the micrometer range are small enough to generate sufficiently high electric field strengths to ignite discharges by applying only moderate voltages (≃500 V).
![]() |
Figure 1 Schematic representation of a negative point-to-plane discharge with metallic electrodes – three-dimensional setup. 100 μm ≤ d ≤ 3 mm, R = 23 MΩ [16]. |
2 Microplasma microphone (2D setup)
In the previous paper on microdischarge microphones [16], theoretical and experimental developments are concentrated on individual discharges. Considering now an array of microdischarges arranged in parallel, also called Microstructured Electrode Array, the electrode system can be used as microphone as given in Figure 2. This device consists of plane electrodes bonded to a substrate (two-dimensional setup). More precisely, the two electrodes of 170 points are mounted in parallel and placed facing a wire. The main body is a silica wafer (SiO2). The electrodes were patterned by photolithography in a chromium-gold layer. A top layer of SiO2 with a thickness of about 0.5 μm is added to cover these electrodes in order to prevent erosion. In order to stabilize microdischarges, each electrode with points is connected to a ballast resistance (R ≃ 23 MΩ).
![]() |
Figure 2 Left side: schematic representation of the microdischarge microphone – two-dimensional setup. Two electrodes with 170 points and a wire electrode. d = 100 μm, L = 17 mm, H = 450 μm, h = 170 μm with a tip radius of approximately 20 μm. R ≃ 23 MΩ and r ≃ 50 Ω are the values of the ballast and shunt resistance. Right side: photograph of a microplasma microphone. |
2.1 Electroacoustic model
The electroacoustic model, which expresses the relation between the variation of the electric current i(t) and the acoustic pressure pa(t), is given by the semi-empirical relation [16]:
The sensitivity Sp is inversely proportional to the ratio of the specific heats and the static pressure P0. It depends on the operating point of the electric discharge (Ud, I) evaluated at P0. This expression is close to the one proposed by Dayton et al. [19]. The value of the coefficient k is deduced from experimental data. For microdischarges with point-to-plane geometry (Fig. 1), the value of k is close to 1.3. In our case of flat microdischarges obtained with microstructured electrode array, k is set to 1.
3 Experimental work
3.1 DC discharge
A discharge cell is generally composed of two electrodes separated by an air gap d (for example: a point and a plane, see Fig. 1; a multi-point and a wire, see Fig. 2) and a ballast resistance R connected in series. When a DC voltage is applied to the discharge cell, the electric discharge formed between the two electrodes mainly depends on (i) the air pressure, (ii) the applied voltage, (iii) the material of the electrodes, and (iv) the geometry of the discharge [1, 25, 26].
3.2 Voltage-current characteristics
The various operating regimes of a DC discharge are determined from the experimental voltage-current characteristic (voltage Ud between the electrodes versus electric current I flowing through the plasma). For point-to-plane discharges (Fig. 1), Figure 3 gives typical examples of voltage-current characteristics. A clear distinction can be observed between millimetric (1 mm < d < 7 mm) and submillimetric discharges (d ≤ 1 mm). The dynamic behaviors of these discharges are described in the following references: [1, 25, 26].
![]() |
Figure 3 Variation of voltage Ud with mean current I associated with a point-to-plane discharge (Fig. 1) – [16]. |
Figure 4 shows the voltage-current characteristic (Ud, I = Ir/2) associated with our microdischarge microphone (Fig. 2). The current Ir collected by the wire electrode is deduced from the voltage drop through a resistance of small value (r ≃ 50 Ω). Voltage and current signals are acquired with a voltmeter (type Agilent 34401A) or a fast oscilloscope (type LeCroy LT 322, 500 MHz bandwidth, 200 Ms/s) for DC or time dependent current measurements, respectively.
![]() |
Figure 4 Variation of voltage Ud with mean current I associated with a microstructured electrode array: two electrodes with 170 points and a wire electrode (see Fig. 2). Comparison between experimental data (×××) and empirical model (–), Equation (2), with the adjusted parameters Us ≃ 820 V and Rd ≃ −1.9 MΩ deduced from a least squares method. |
Due to space-charge effects between the electrodes, the microdischarges have a self-oscillating behavior [27, 28]. The electric current is self-pulsing with a repetition rate of a few tens of kilohertz and pulse durations of the order of a few tens of nanoseconds. It should be noted that array defaults affect the uniform distribution of current between points, ultimately limiting the number of microdischarges that can be created in parallel. With the bombardment of the electrodes by charged particles, the overall shape of the electrodes evolves with time. Microdischarges appear and disappear, and the electric current has a more or less erratic evolution. The particular morphology of this current makes it difficult to estimate its mean value.
The voltage-current characteristic (Fig. 4) displays a negative differential resistance (), an electrical evolution which is generally associated with the self-oscillating system [29]. The discharge voltage Ud decreases approximately linearly with the mean current I. Its evolution can be modeled using the relation:
(2)where Us ≃ 820 V is the threshold voltage associated with the microdischarge start-up and Rd ≃ −1.9 MΩ is the differential resistance. Values of Us and Rd are deduced from a least squares method. In order to avoid the transition to the spark and stabilize the discharge [24], the Kaufmann criterion must be ensured: Rd + R > 0 which is the case with a ballast resistance R close to 23 MΩ.
3.3 Estimating acoustic pressure with a reference microphone and a microplasma microphone
The details and performance of the experimental device used (Fig. 5) are discussed in more details in a previous paper devoted to the plasma microphone [16]. It enables the comparison of the value of the sound pressure deduced from plasma microphone to the one of a reference microphone (using a comparison calibration method). First, acoustic pressure at the center of the tube is measured with a reference microphone (not shown in Fig. 5), the microphone is flush-mounted with the inside wall of the tube. Note that the microplasma microphone is maintained inside the tube in order to take into account its influence on the acoustic field. Then, the acoustic pressure is measured with the microplasma microphone (the reference microphone being removed). As previously described in [16], a computer program is used to drive the frequency, amplitudes, and phases of a dual-channel signal generator (Tektronix AFC – 3022C) which supplies sinusoidal signals to the loudspeakers. A Lock-in Amplifier (SR830 DSP Stanford Research Systems) carries out a synchronous demodulation of its input (voltage from the microphone) by locking its internal oscillator on the phase reference received from the generator (synchronisation output). The measured data are then post-processed by the computer.
![]() |
Figure 5 Experimental device used to control the sound pressure at the center of the tube. The sound pressure is first measured with a reference microphone and then with a microplasma microphone. A Faraday cage is placed around a part of the waveguide. L = 455 mm and Rt = 21.9 mm. |
Figure 6 shows the sound pressure levels measured in the waveguide with the plasma microphone (with gap length d = 100 μm) and the reference microphone for two voltages applied to the loudspeakers (VL = 2 and 3 VRMS). The sensitivity of the plasma microphone is obtained by adjusting its frequency response to that of the reference microphone.
![]() |
Figure 6 Sound Pressure Level measured with a microplasma microphone (d = 100 μm) and a reference microphone for two voltages VL applied to the loudspeakers. Magnitude in dB SPL: 20 log(Pmic/Pref) with Pref = 20 × 10−6 Pa. Operating point of the discharge: Ud ≃ 680 V, I ≃ 70 μA. Fitted sensitivities: Sp2V ≃ 0.46 × 10−9 A/Pa and Sp3V ≃ 0.5 10−6 A/Pa. |
In the frequency range 100–400 Hz, the acoustic device provides an acoustic pressure close to 355 Pa (≃145 dB SPL), which represents a variation in atmospheric pressure P0 of approximately 0.35%. The plot also reveals peaks in the frequency response (540 Hz, 1.17 kHz, 1.84 kHz, 2.51 kHz, 3.17 kHz, and 3.82 kHz) which are the resonances of the air volume included in the waveguide [16]. Note that the microplasma microphone can measure small pressure fluctuations close to 6 Pa (110 dB SPL). The “adjusted” sensitivity of the microplasma microphone is Sp ≈ 0.48 × 10−9 A/Pa. Knowing the operating parameters of the microdischarge, the semi-empirical model (Eq. (1)) gives a sensitivity value Sp = 0.49 × 10−9 A/Pa. The predictions of the empirical model are good despite the difficulties in estimating the mean value of the electric current.
The frequency responses in Figure 6 also reveal pressure peaks (with a low amplitude) at frequencies of ≃840 Hz, 1.5 kHz, and 2.2 kHz. As described in reference [16], this is the signature of a sensitivity of the microplasma sensor to the particle velocity. Separating the information on acoustic pressure and particle velocity is therefore necessary. The architecture of the electrodes must be adapted to this function by taking inspiration from anemometry using electric discharges [13–15, 30] for example.
Figure 7 shows the second electrode structure used as microphone. A disk-shaped electrode serves as a single cathode and the anode is a ring-shaped electrode (electrodes without a top layer of SiO2). A ballast resistor (R ≃ 23 MΩ) prevents the transition to the spark. This three-electrode system is designed for particle velocity measurement [13–15, 30]. As in the previous electrode structure (Fig. 1), the electric current is self-oscillating and its erratic character is more pronounced than in the previous electrode system. This fact is mainly due to the absence of a SiO2 layer on the electrodes. The constant bombardment of the electrodes by charged particles erodes their surface more rapidely and locally changes the inter-electrode distance.
![]() |
Figure 7 Schematic representation of the microdischarge microphone. The cathode is a disk-shaped electrode. Both anodes are ring-shaped, only one is used. d = 45 μm and D = 60 μm. R ≃ 23 MΩ and r ≃ 50 Ω are the values of the ballast and shunt resistance. |
Figure 8 shows the voltage-current characteristic (Ud, I) associated with this electrode structure (Fig. 7). As in the previous case, the discharge voltage Ud decreases approximately linearly with the mean current I (). Its evolution can be modeled using the relation (2) with Us ≃ 595 V and Rd ≃ −2.9 MΩ.
![]() |
Figure 8 Variation of voltage Ud with current I associated with the microstructured electrode of Figure 7. Comparison between experimental data (×××) and empirical model (–), Equation (2), with the adjusted parameters Us ≃ 595 V and Rd ≃ −2.9 MΩ deduced from a least squares method. |
The sensitivity of this microplasma microphone (Fig. 7) is deduced from the experimental setup (waveguide and comparison calibration method) used previously. Figure 9 gives the frequency response of the reference microphone and that of the microplasma microphone (Fig. 7). Its sensitivity is estimated close to 0.4 × 10−9 A/Pa. This frequency response reveals a pressure peak at ≃840 Hz. As in the previous electrode architecture, this sensor also has a sensitivity to the particle velocity. After 2 kHz, Figure 9 shows a significant discrepancy between the frequency responses of the microplasma microphone and the reference microphone. The reason for this difference however is not clear and this tendency must be confirmed by complementary measurements. Knowing the operating parameters of the microdischarge, the empirical model (Eq. (1)) gives a sensitivity value Sp = 0.42 × 10−9 A/Pa. As for the previous case, the predictions of the model are in quite good agreement with the experiment considering the difficulties in estimating the mean value of the electric current. Note that Figure 9 provides a unique frequency response comparison of microphone because the electrode system, as designed, has a limited lifetime, about 15 min compared to 2 h for points systems with a top layer of SiO2.
![]() |
Figure 9 Sound Pressure Level measured with a microdischarge microphone (d = 45 μm) and a reference microphone for various voltages VL applied to the loudspeakers. Magnitude in dB SPL: 20 log(Pmic/Pref) with Pref = 20 × 10−6 Pa. Operating point of the discharge: Ud ≃ 420 V, I ≃ 60 μA. Fitted sensitivity: Sp2V ≃ 0.4 × 10−9 A/Pa. |
4 Summary
This work completes the experimental work of the same authors [16] on the microplasma microphones with point-to-plane geometry. In this paper, we have shown experimentally that a microplasma created by microstructured electrode array is sensitive to sound pressure. The sensitivity of these sensors close to 0.4 nA/Pa is estimated using a waveguide and a calibration method by comparison with a reference microphone. Concerning the electroacoustic sensitivity of these microplasma microphones, the predictions of the proposed empirical model are in good agreement with the experimental data. Unfortunately, the electrode systems as they were manufactured are fragile and their lifetime is limited. This work constitutes a first step in the development of a microplasma microphone. Many theoretical, technical and experimental problems remain to be solved.
Conflict of interest
Author declared no conflict of interests.
Acknowledgments
The authors would like to thank James Blondeau for his assistance in the experiments and his technical advice. Also we would like to thank anonymous reviewers for their valuable comments. This research was funded by the “Région des Pays de la Loire” in the research project MEMSPA (Micro moteurs électrodynamiques pour la réalisation de parois acoustiques absorbantes).
References
- K.H. Becker, U. Kogelschatz, K.H. Schoenbach, R.J. Barker (Eds.): Non-equilibrium air plasmas at atmospheric pressure. Institute of Physics Publishing, London, 2005. [Google Scholar]
- P. Bruggeman, R. Brandenburg: Atmospheric pressure discharge filaments and microplasmas: physics, chemistry and diagnostics. Journal of Physics D: Applied Physics 46 (2013) 464001. [CrossRef] [Google Scholar]
- P. Bruggeman, F. Iza, R. Brandenburg: Foundations of atmospheric pressure nonequilibrium plasmas. Plasma Sources Science and Technology 26 (2017) 123002. [CrossRef] [Google Scholar]
- J.R. Dwyer, M.A. Uman: The physics of lightning. Physics Reports 534 (2014) 147–241. [CrossRef] [Google Scholar]
- M.F.E. Barron: Auditorium acoustics and architectural design. Spun, London, 1993. [Google Scholar]
- C. Ayrault, Ph Béquin, S. Baudin: Characteristics of a spark discharge as an adjustable acoustic source for scale model measurements, in: Proceeding of the Acoustics 2012, Nantes, France, 2012. [Google Scholar]
- W. Du Bois Duddell: The musical arc. The Electrician 52 (1901) 902. [Google Scholar]
- J.-M. Ginoux: History of Nonlinear Oscillations Theory in France (1880–1940). Springer, Berlin Heidelberg, 2017. [CrossRef] [Google Scholar]
- F. Bastien: Acoustics and gas discharges: applications to loudspeakers. Journal of Physics D: Applied Physics 20 (1987) 1547–1557. [CrossRef] [Google Scholar]
- M.S. Mazzola, G.M. Molen: Modeling of a DC glow plasma loudspeaker. Journal of the Acoustical Society of America 81 (1987) 1972–1978. [CrossRef] [Google Scholar]
- Ph Béquin, K. Castor, Ph Herzog, V. Montembault: Modeling plasma loudspeakers. Journal of the Acoustical Society of America 121 (2007) 1960–1970. [CrossRef] [Google Scholar]
- Y. Sutton: Electro-acoustic coupling in a plasma gas. PhD dissertation, The Open University, Milton Keynes, UK, 2011. [Google Scholar]
- Ph Béquin, V. Joly, Ph Herzog: Corona discharge velocimeter. Acta Acustica United With Acustica 104 (2018) 477–485. [CrossRef] [Google Scholar]
- F.C. Lindvall: A glow discharge anemometer. IEEE 53 (1934) 1068–1073. [Google Scholar]
- P.A. Durbin, D.J. Mckinzie, E.J. Durbin: An anemometer for highly turbulent or recirculating flows. Experiments in Fluids 5 (1987) 184–188. [CrossRef] [Google Scholar]
- Ph Béquin, A. Nanda Tonlio, S. Durand: Air plasma sensor for the measurement of sound pressure using millimetric and micrometric discharges. Journal of Applied Physics 127 (2020) 034502. [CrossRef] [Google Scholar]
- P. Thomas: A diaphragmless microphone for radio broadcasting, in: Convention of the AIEE, New York, 1923. [Google Scholar]
- I. Dyer, B.W. Blum, U. Ingard: The interaction of a sound wave with a point-to-plane corona discharge. Journal of the Acoustical Society of America 25 (1953) 829–829. [CrossRef] [Google Scholar]
- J.A. Dayton, J.T. Verdeyen, P.F. Virobik: Method for detecting weak sound waves in a low pressure gas. Review of Scientific Instruments 34 (1963) 1451–1452. [CrossRef] [Google Scholar]
- W.R. Babcock, R.W. Hermsen: Glow discharge microphone. Review of Scientific Instruments 41 (1970) 1659–1660. [CrossRef] [Google Scholar]
- F.J. Fransson, E.V. Jansson: The stl-ionophone: transducer properties and construction. Journal of the Acoustical Society of America 58 (1975) 910–915. [CrossRef] [Google Scholar]
- H. Akino, H. Shimokawa, T. Kikutani, J. Green: On the study of the ionic microphone. Journal of the Audio Engineering Society 62 (2014) 254–264. [CrossRef] [Google Scholar]
- Ph Béquin, V. Joly, Ph Herzog: Modeling of a corona discharge microphone. Journal of Physics D: Applied Physics 46 (2013) 175204. [CrossRef] [Google Scholar]
- K.H. Schoenbach, K. Becker: 20 years of microplasma research: a status report. European Physical Journal D 70 (2016) 1–22. [CrossRef] [Google Scholar]
- M. Goldman, A. Goldman: Corona discharges, in: Gaseous Electronics, Hirsh M.N., Oskam H.J., Editors, Academic Press, New York, 1978. [Google Scholar]
- Y.P. Raiser: Gas Discharge Physics. Springer-Verlag, Berlin Heidelberg, 1991. [Google Scholar]
- V.P. Nagorny: Statistical instability of barrier microdischarges operating in townsend regime. Journal of Applied Physics 101 (2007) 023302. [CrossRef] [Google Scholar]
- C. Lazzaroni, P. Chabert: Discharge resistance and power dissipation in the self-pulsing regime of micro-hollow cathode discharges. Plasma Sources Science and Technology 20 (2011) 055004. [CrossRef] [Google Scholar]
- A. Jenkins: Self-oscillation. Physics Reports 525 (2013) 167–222. [NASA ADS] [CrossRef] [Google Scholar]
- M.D. Yamanaka, H. Hirosawa, Y. Matsuzaka: Glow-discharge ionic anemometer. Review of Scientific Instruments 56 (1985) 617–622. [CrossRef] [Google Scholar]
Cite this article as: Béquin P. Nanda Tonlio A. & Durand S. 2021. Microplasma microphones. Acta Acustica, 5, 37.
All Figures
![]() |
Figure 1 Schematic representation of a negative point-to-plane discharge with metallic electrodes – three-dimensional setup. 100 μm ≤ d ≤ 3 mm, R = 23 MΩ [16]. |
In the text |
![]() |
Figure 2 Left side: schematic representation of the microdischarge microphone – two-dimensional setup. Two electrodes with 170 points and a wire electrode. d = 100 μm, L = 17 mm, H = 450 μm, h = 170 μm with a tip radius of approximately 20 μm. R ≃ 23 MΩ and r ≃ 50 Ω are the values of the ballast and shunt resistance. Right side: photograph of a microplasma microphone. |
In the text |
![]() |
Figure 3 Variation of voltage Ud with mean current I associated with a point-to-plane discharge (Fig. 1) – [16]. |
In the text |
![]() |
Figure 4 Variation of voltage Ud with mean current I associated with a microstructured electrode array: two electrodes with 170 points and a wire electrode (see Fig. 2). Comparison between experimental data (×××) and empirical model (–), Equation (2), with the adjusted parameters Us ≃ 820 V and Rd ≃ −1.9 MΩ deduced from a least squares method. |
In the text |
![]() |
Figure 5 Experimental device used to control the sound pressure at the center of the tube. The sound pressure is first measured with a reference microphone and then with a microplasma microphone. A Faraday cage is placed around a part of the waveguide. L = 455 mm and Rt = 21.9 mm. |
In the text |
![]() |
Figure 6 Sound Pressure Level measured with a microplasma microphone (d = 100 μm) and a reference microphone for two voltages VL applied to the loudspeakers. Magnitude in dB SPL: 20 log(Pmic/Pref) with Pref = 20 × 10−6 Pa. Operating point of the discharge: Ud ≃ 680 V, I ≃ 70 μA. Fitted sensitivities: Sp2V ≃ 0.46 × 10−9 A/Pa and Sp3V ≃ 0.5 10−6 A/Pa. |
In the text |
![]() |
Figure 7 Schematic representation of the microdischarge microphone. The cathode is a disk-shaped electrode. Both anodes are ring-shaped, only one is used. d = 45 μm and D = 60 μm. R ≃ 23 MΩ and r ≃ 50 Ω are the values of the ballast and shunt resistance. |
In the text |
![]() |
Figure 8 Variation of voltage Ud with current I associated with the microstructured electrode of Figure 7. Comparison between experimental data (×××) and empirical model (–), Equation (2), with the adjusted parameters Us ≃ 595 V and Rd ≃ −2.9 MΩ deduced from a least squares method. |
In the text |
![]() |
Figure 9 Sound Pressure Level measured with a microdischarge microphone (d = 45 μm) and a reference microphone for various voltages VL applied to the loudspeakers. Magnitude in dB SPL: 20 log(Pmic/Pref) with Pref = 20 × 10−6 Pa. Operating point of the discharge: Ud ≃ 420 V, I ≃ 60 μA. Fitted sensitivity: Sp2V ≃ 0.4 × 10−9 A/Pa. |
In the text |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.