Open Access

Table 3

Average detection times of reversing alarms using binaural reproduction with headphones.

Subject # Tonal ADT [1] Broadband ADT [1] Undetected alarms (%) Click score (%)
S1 13.370 14.246 5.00 95.00
S2 10.627 13.013 0.00 97.00
S3 12.924 13.235 5.00 78.50
S4 11.561 14.860 5.00 88.50
S5 13.317 13.746 5.00 94.25
S6 12.456 12.254 0.00 99.25
S7 13.660 15.156 0.00 89.75
S8 12.406 13.597 2.50 95.75
S9 11.165 10.701 5.00 99.50
S10 12.699 14.185 2.50 98.75
S11 9.063 10.569 2.50 97.25
S12 11.203 11.338 0.00 98.00
S13 11.980 13.821 2.50 96.50
S14 10.929 12.318 0.00 99.75
S15 12.092 13.656 2.50 95.25
S16 11.813 13.158 7.50 84.50
S17 13.165 13.258 0.00 98.00
S18 12.088 12.842 0.00 93.75
S19 12.290 12.011 2.50 98.75
S20 11.577 13.219 2.50 98.25
Mean 12.019 13.059 2.50 94.81

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.