Description of the six test rooms. The reverberation time (T20) and clarity indices for speech (C50) were averaged across the 500 Hz and 1 kHz octave bands. T20 and C50 values were averaged over twelve transducer-receiver combinations. For C50 the standard deviation (SD) across different measurement positions is given.

Room Dimensions (l × w × h) (m) Volume (m3) T20 (s) C50 (dB)
Mean SD
LB anechoic 4.3 × 4.6 × 2.4 47.47 <0.05
OL anechoic 3.5 × 3.1 × 2.1 77.18 <0.05
LB room 1 2.6 × 3.6 × 2.5 23.40 0.10 30.6 2.5
OL room 1 2.4 × 2.4 × 2.2 12.67 0.11 28.2 1.3
LB room 2 4.8 × 3.3 × 2.4 38.02 0.24 13.2 1.3
OL room 2 3.9 × 4.0 × 2.5 39.00 0.11 28.7 2.0

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.