Open Access

Table 3.

List of contributions to Type B uncertainties.

Source of uncertainty Notes Value (half-width x) Conversion to [dB] Statistical distribution Standard uncertainty u [dB]
Condenser microphone
  Sensitivity Manufacturer’s 0.08 [dB] NA Rectangular 0.046
  frequency response1 data 1 [dB] 0.57
Instrumentation
Laser meter Manufacturer’s
data
0.15 [mm] max(|20log(d+xd)|, |20log(dxd)|)$ max(|20\log(\frac{d + x}{d})|,|20\log(\frac{d - x}{d})|) $ Rectangular ≈0
Compass Manufacturer’s
data
max(|20log(θ+xθ)|, |20log(θxθ)|)$ max(|20\log(\frac{\theta + x}{\theta})|, |20\log(\frac{\theta - x}{\theta})|) $ Rectangular 0.132
Environment3
  Temperature
  Pressure
  Humidity [10, 21] 3 [dB] NA Rectangular 1.73
  Wind

110 [Hz]–25 [kHz]. 2 θ = 81°. 3Average conditions.