Open Access

Table A.2.

Statistical summary comparing sonAIR BASIC mode for GVA (2019) and ZRH (2017, 2019) with the best-practice model across all sound exposure levels (low, moderate, high) and time periods (06–22 h, 22–23 h, 23–05 h). Mean (μ), standard deviation (σ), minimum (min), and maximum (max) differences are shown.

GVA2019 ZRH2017 ZRH2019
sonAIR BASIC − sonAIR BASIC − sonAIR BASCIC −
best-practice model best-practice model best-practice model
Low Moderate High Low Moderate High Low Moderate High
06–22 h μ 0.1 −0.4 −1.0 0.1 −0.3 −0.9 0.2 −0.4 −1.8
σ 1.0 1.2 0.7 1.2 1.1 1.4 1.3 1.1 1.1
min −13.5 −9.9 −3.3 −12.2 −8.0 −4.7 −8.2 −8.2 −5.2
max 5.3 3.0 0.7 5.5 5.1 7.5 4.8 4.6 1.7
22–23 h μ 2.0 0.3 −0.6 1.3 −0.5 −0.3 1.8 −0.5 −0.4
σ 1.3 1.2 1.4 1.2 1.3 1.2 1.5 1.3 1.3
min −10.8 −11.8 −9.5 −11.4 −14.6 −9.4 −12.7 −17.4 −9.7
max 6.2 4.1 1.5 6.3 7.5 5.5 6.7 7.7 5.1
23–05 h μ 2.8 0.1 −1.6 −0.1 −0.4 0.2 −0.3 −0.4 −0.2
σ 1.9 1.5 0.8 1.2 1.5 2.0 1.1 1.6 2.1
min −8.6 −12.6 −4.7 −15.7 −16.1 −8.7 −14.5 −17.7 −7.8
max 6.8 3.8 0.3 6.3 8.9 11.0 6.5 9.9 6.2

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.