Figure 6

image

Download original image

Convergence rates of time and space. For the latter, linear (p1) and quadratic (p2) FE basis functions and different duct lengths (l0 to l6) are considered. The dashed grey lines indicate specific orders of convergence. (a) Temporal convergence of configuration h5, p2, l0; (b) Spatial convergence with the finest considered time discretization t5t = 7.8125 μs).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.