Open Access

Table 3.

Summary of a GLM assessing the effects loudness, application type, and device ID on differences in SPL measurements from a standard SLM for measuring the loudness of white noise.

Term Estimate Std. Error t value Pr(> |t|)
(Intercept) −9.80536 2.04202 −4.802 7.58e−06
Loudness 0.13898 0.02529 5.496 4.85e−07
Keuwlsoft 1.73103 2.89683 0.598 0.551886
KTW 12.55968 2.91559 4.308 4.81e−05
Device 5.51005 2.88785 1.908 0.060118
Loudness × Keuwlsoft −0.01879 0.03574 −0.526 0.600531
Loudness × KTW −0.17830 0.03596 −4.958 4.14e−06
Loudness × Device −0.07331 0.03576 −2.050 0.043770
Keuwlsoft × Device −2.62062 4.09674 −0.640 0.524277
KTW × Device −13.52402 4.16967 −3.243 0.001748
Loudness × Keuwlsoft × Device 0.02902 0.05055 0.574 0.567582
Loudness × KTW × Device 0.18870 0.05162 3.656 0.000466