Table 5.

Summary of a GLM assessing the effects of frequency, loudness, pseudo-calibration status, device ID, and the use of the Frequency Analyzer feature on differences in SPL measurements from a standard SLM in the Bolden application.

Term Estimate Std. Error t value Pr(> |t|)
(Intercept) −21.721704 6.807244 −3.191 0.001504
Frequency 0.317027 0.953012 0.333 0.739527
Loudness 0.285037 0.078056 3.652 0.000287
Pseudo-calibration 14.522581 7.016180 2.070 0.038958
Frequency Analyzer −3.095457 2.970952 −1.042 0.297939
Device 2.899968 6.480437 0.447 0.654703
Frequency × Loudness 0.012062 0.011518 1.047 0.295483
Frequency × Pseudo-calibration −2.471041 0.988237 −2.500 0.012710
Loudness × Pseudo-calibration −0.109883 0.081082 −1.355 0.175938
Loudness × Frequency Analyzer 0.023004 0.036588 0.629 0.529799
Frequency × Device 1.419707 0.885051 1.604 0.109300
Loudness × Device 0.004048 0.071836 0.056 0.955089
Pseudo-calibration × Device 9.144370 2.445285 3.740 0.000205
Frequency Analyzer × Device 10.525935 4.023482 2.616 0.009152
Frequency × Loudness × Pseudo-calibration 0.034504 0.011896 2.901 0.003883
Frequency × Loudness × Device −0.036719 0.010288 −3.569 0.000391
Frequency × Pseudo-calibration × Device −0.746023 0.347093 −2.149 0.032067
Loudness × Frequency Analyzer × Device −0.129937 0.049706 −2.614 0.009206